How it works
The high-side driver of a half bridge is powered from a capacitor that floats on the switch node. It is refilled through the bootstrap diode only while the low-side switch conducts, and it has to supply everything the high side needs during the longest high-side on-time: the gate charge, a small level-shifter charge per cycle, and the floating section's quiescent current plus any leakage, including the current of a gate-source resistor. Adding these gives the charge Q drawn per cycle, and dividing by the allowed droop gives the classic minimum capacitance C ≥ Q/ΔV, the same method used in the bootstrap guide on this site.
That rule silently assumes the capacitor is fully topped up in every low-side interval. The calculator also checks this. With a series resistance R in the charging path (a deliberate resistor plus the diode's dynamic resistance) the capacitor recharges with time constant R·C, and the low-side time is (1 − D)/f_s. Taking the charge balance over one cycle in steady state gives the lowest voltage the capacitor reaches, V_lo = V_DD − V_F − (Q/C)/(1 − e^(−t_LS/RC)). When t_LS is long compared with RC the extra factor is 1 and the result is the usual one. When t_LS is short, the factor grows and V_lo approaches V_DD − V_F − Q·R/t_LS, which no longer depends on C at all. A bigger capacitor then does not help; only a smaller R or a shorter maximum duty does.
Ceramic capacitors lose capacitance under DC bias, often by half or more for small, low-voltage X7R or X5R parts at their working voltage. The page applies the share you enter to get the effective capacitance, and reports the nominal value you would have to place. At start-up the capacitor is empty, so the first low-side pulses charge it through R from zero; the page counts how many are needed to reach V_min and shows the initial peak current, which the diode and the V_DD decoupling have to handle.
The chart repeats the steady-state calculation for every duty cycle from 1 to 99 %. Its knee shows the highest duty at which the bootstrap supply still keeps up, which is the number to compare with the controller's maximum duty limit or with the longest on-time during a transient.
Design procedure
- 1Collect Q_g at your gate voltage, the driver's Q_LS and I_QBS, and any leakage including a gate-source resistor.
- 2Enter the switching frequency and the largest duty the high side can reach, including transients.
- 3Set V_min from the high-side UVLO or the required gate voltage, whichever is higher.
- 4Pick a capacitor, enter its retained capacitance at V_DD, and check that the nominal minimum is met.
- 5Check the steady-state minimum and the recharge share; if recharge is slow, reduce R or limit the duty instead of adding capacitance.
- 6Confirm the start-up peak current against the diode rating and give V_DD at least ten times the bootstrap capacitance in decoupling.
Formulas
- Charge per high-side on-time
- Q = Q_g + Q_LS + (I_QBS + I_leak)·t_on, t_on = D_max/f_s
- Minimum capacitance (full recharge)
- C_eff ≥ Q/(V_DD − V_F − V_min), C_nominal = C_eff/retained share
- Steady-state minimum with RC recharge
- V_lo = V_DD − V_F − (Q/C_eff)/(1 − e^(−t_LS/(R·C_eff))), t_LS = (1 − D_max)/f_s
- Short low-side time limit
- t_LS ≪ R·C: V_lo ≈ V_DD − V_F − Q·R/t_LS
- Start-up
- n = ⌈ln(V_t/(V_t − V_min)) · R·C_eff / t_LS⌉, I_pk = (V_DD − V_F)/R
Worked example
The defaults reproduce the example in the bootstrap guide: a 60 nC MOSFET, a driver with 5 nC level-shifter charge and 100 µA quiescent current, 10 µA leakage, 10 kHz at 50 % duty, a 12 V supply, 0.6 V diode drop and a 10.9 V minimum. The charge per cycle is 70.5 nC and the effective capacitance must be at least 141 nF. If the 470 nF part keeps only 60 % at 12 V, that is 282 nF effective, so the nominal requirement becomes 235 nF and the 470 nF part meets it. With 10 Ω in series the time constant is 2.8 µs, far shorter than the 50 µs low-side time, so the capacitor is fully refilled and V_BS dips to 11.15 V, 0.25 V above the minimum. A 10 kΩ gate-source resistor would add about 1.2 mA and raise the charge to 130.5 nC, leaving only 37 mV of margin. Pushing the duty to 98 % leaves 2 µs of low-side time, less than one time constant, and V_BS falls to 10.87 V, below the minimum. A second case shows the trap: 150 nC at 20 kHz and 95 % duty with 20 Ω and 1 µF that keeps 70 % at bias. The classic formula asks for only 223 nF nominal, yet the steady-state minimum is 11.96 V against a 12.5 V requirement, because each 2.5 µs low-side interval refills only 16 % of the droop. Dropping R to 2 Ω lifts the minimum to 13.6 V, at the price of a 7 A first charging pulse. The steady-state and start-up values were checked against a cycle-by-cycle time-step simulation in Python.
Common mistakes
- Sizing C from Q/ΔV and never checking that the low-side time is long enough to refill it.
- Using the nominal capacitance of a small ceramic capacitor that keeps less than half of it at 12 to 15 V.
- Forgetting the gate-source resistor, which can draw more charge per cycle than the gate itself at low frequency.
- Running the high side at or near 100 % duty with a bootstrap supply, which cannot recharge without a low-side interval.
- Using a slow diode whose reverse-recovery charge comes back out of the bootstrap capacitor every cycle.
Frequently asked questions
Why does the calculator say a larger bootstrap capacitor does not help?
Because when the low-side interval is short compared with R·C, the capacitor only recovers a fraction of what it lost each cycle, and in steady state its voltage settles where the small recharge current over t_LS equals the charge drawn. That point is roughly Q·R/t_LS below V_DD − V_F, independent of C. A larger capacitor droops less per cycle but also refills more slowly, and the two effects cancel. The fixes are a lower series resistance, a faster diode, or a lower maximum duty.
What should I enter for the retained capacitance?
Look up the DC-bias characteristic of the exact part at your V_DD, usually in the manufacturer's online tool. Small-case X7R and X5R capacitors rated at 16 V or 25 V can lose 40 to 70 % of their capacitance at 12 to 15 V. A higher voltage rating or a larger case keeps more. Then also allow for tolerance and temperature.
Which minimum voltage should I use?
The higher of two values: the high-side undervoltage-lockout threshold from the driver datasheet plus some margin, so the driver never trips, and the gate voltage at which the switch reaches the on-resistance you designed for. For a MOSFET specified at 10 V that is often the binding one; for SiC devices driven at 15 to 18 V it almost always is.
Is the series resistor necessary?
Not always, but the charging path always has some resistance, at least the diode's dynamic resistance, and a few ohms is common to limit the start-up surge and the current spikes when the switch node moves. The calculator needs a value above zero. If the result shows slow recharge, the resistor is the first thing to reduce.
How were the numbers checked?
A separate Python program simulates the capacitor cycle by cycle: it removes the gate and level-shifter charge at turn-on, integrates the quiescent and leakage current over the on-time, and integrates the RC recharge over the low-side time in small steps until the voltage repeats. Its minimum and maximum V_BS and the start-up pulse count match the calculator, and the 70.5 nC and 141 nF of the first example match the bootstrap guide.
References
- International Rectifier (now Infineon), design tip DT98-2, "Bootstrap Component Selection For Control IC's" (the charge the bootstrap capacitor must supply: gate charge, level-shifter current, leakage).
- Texas Instruments, application report SLUA887, "Bootstrap Circuitry Selection for Half-Bridge Configurations" (capacitor, diode and resistor selection, start-up charging, and V_DD bypass at least ten times the bootstrap capacitor).
- The steady-state and start-up values on this page were recomputed independently with a cycle-by-cycle simulation in Python.
Results are engineering estimates. Verify your design with datasheets, simulation and measurement.