PCB Trace Width Calculator: Current Capacity, Temperature Rise and Voltage Drop (IPC-2221)

Find the copper width a PCB trace needs to carry a current for a given temperature rise, on an outer or inner layer, using the IPC-2221 curve fit. Also gives the trace resistance at operating temperature, voltage drop, power loss and current density, with width-versus-current curves.

Trace

1 oz/ft² is about 35 µm of copper. The temperature rise is above the board around the trace; resistance is calculated at ambient plus ΔT.

Minimum width

2.38 mm

93.6 mil

Same current on the other layer

6.18 mm

Inner layer

Voltage drop

121 mV

R = 12.1 mΩ at operating temperature

Power in the trace

1.21 W

trace at 60 °C

Details

Copper thickness
69.6 µm
Cross-section
0.165 mm² (256 mil²)
Current density
60.5 A/mm²
Resistance per centimetre
1.21 mΩ/cm

Width needed against current, 2 oz copper

Width grows faster than current: doubling the current needs about 2.6 times the cross-section, because the fit goes as A^0.725. Allowing twice the temperature rise saves about a third of the width.

IPC-2221 curve fit for a single isolated trace. Nearby planes, copper pours, vias, board thickness and airflow can change the real temperature rise considerably; IPC-2152 gives charts that account for some of these. Check hot spots on high-current boards with a thermal camera.

How it works

A PCB trace heats up because of its own resistance, and the question for design is how wide it must be so that the temperature rise stays acceptable. The most widely used answer is the curve fit published with IPC-2221, which goes back to test data first charted in the older IPC-D-275 standard: I = k·ΔT^0.44·A^0.725, with the cross-section A in square mils, the rise ΔT in °C, and k = 0.048 for outer layers and 0.024 for inner layers. The calculator solves that equation for the cross-section and divides by the copper thickness to get the width.

Two features of the fit matter in practice. The exponent 0.725 means that current does not scale with area: doubling the current needs about 2.6 times the cross-section, because a wider trace does not get proportionally more surface to shed heat. And the inner-layer factor is half of the outer one, which means an inner trace needs about 2.6 times the width of an outer one for the same current and rise. That halving was a conservative assumption. The later IPC-2152 standard, based on new measurements, found that inner traces are often not that much worse, and that nearby copper planes and board thickness matter more than the layer itself.

The temperature rise is only half of the design. The same copper has a resistance that causes a voltage drop and a power loss, and both matter in power circuits, for example on a current-sense path or a low-voltage high-current rail. The calculator computes the resistance at the trace's operating temperature, ambient plus ΔT, with copper's temperature coefficient of about 0.39 %/°C, and from it the voltage drop and the loss along the length you enter.

The fit is an empirical curve with a limited range: roughly up to 35 A, temperature rises from 10 to 100 °C and widths up to about 400 mil. Outside it the page still gives a number but flags it, and the safer route is the IPC-2152 charts, a thermal simulation, or measuring a prototype.

Design procedure

  1. 1Take the RMS current the trace carries continuously, not the peak.
  2. 2Choose the allowed temperature rise from the board material, nearby parts and the ambient temperature.
  3. 3Enter the copper weight and layer, and read the minimum width; add margin for etching tolerance.
  4. 4Check the voltage drop and the loss along the actual length, especially on low-voltage rails and sense paths.
  5. 5For currents above about 35 A, very wide traces or tight thermal margins, confirm with IPC-2152 charts, a thermal simulation or a measurement.

Formulas

IPC-2221 current capacity
I = k·ΔT^0.44·A^0.725, A in mil², k = 0.048 (outer), 0.024 (inner)
Cross-section and width
A = (I/(k·ΔT^0.44))^(1/0.725), w = A/t, t ≈ 34.8 µm per oz/ft²
Resistance at operating temperature
R = ρ20·(1 + 0.00393·(T_amb + ΔT − 20))·L/A, ρ20 = 1.724·10⁻⁸ Ω·m
Drop and loss
V = I·R, P = I²·R

Worked example

The defaults are a 10 A trace on a 2 oz outer layer, allowed to rise 20 °C above a 40 °C board, 100 mm long. The fit asks for 256 mil², which with 70 µm copper is 2.38 mm (94 mil) wide. On an inner layer the same current would need 6.18 mm. At its operating temperature of 60 °C the trace has 12.1 mΩ, so it drops 121 mV and dissipates 1.2 W over its length, which is worth knowing on a 3.3 V or 5 V rail. The current density is about 60 A/mm². Allowing a 40 °C rise narrows the outer trace to about 1.56 mm, while 1 oz copper would double the width to 4.75 mm. As a check on the formula, 1 A with a 10 °C rise on 1 oz outer copper gives 0.30 mm, or 11.9 mil, close to the 11.8 mil that most IPC-2221 calculators quote with slightly thicker nominal copper. These values were recomputed in a separate Python implementation in different units.

Common mistakes

  • Sizing for the peak current of a pulsed waveform instead of its RMS value, or the opposite for long pulses.
  • Forgetting that inner layers are derated under IPC-2221, or applying the inner-layer derating where a plane spreads the heat.
  • Ignoring the voltage drop on a high-current, low-voltage rail even when the temperature rise is fine.
  • Using 1 oz thickness for a board that is finished with thinner copper or that loses copper in etching.
  • Leaving a narrow neck at a connector or component pad that carries the full current.

Frequently asked questions

Why does an inner trace need so much more width?

IPC-2221 halves the factor k for inner layers, assuming an embedded trace cannot shed heat to the air. Because of the 0.725 exponent, halving k raises the needed cross-section by a factor of 2^(1/0.725), about 2.6. Measurements behind IPC-2152 suggest this is conservative for many boards, because heat spreads through the laminate and into nearby planes. The calculator follows IPC-2221 and shows both layers so you can see the difference.

Is IPC-2221 or IPC-2152 the right one to use?

IPC-2152 is the newer standard and is based on more extensive testing, including the effects of board thickness, copper planes and mounting. Its charts are more accurate but not reducible to a single formula. IPC-2221 is still widely used for quick sizing and is what most online calculators implement. For high-current or thermally tight designs, use IPC-2152 or a thermal simulation and verify on hardware.

What temperature rise should I allow?

10 °C is a common conservative choice for signal and general power traces; 20 to 30 °C is often accepted for high-current paths if the board material, nearby components and solder joints tolerate the resulting temperature. The trace temperature is ambient plus the rise, so a board already at 70 °C leaves less room.

Does a via or a narrow neck change the result?

Yes. The calculation is for a uniform trace. A short narrow neck is partly cooled by the wider copper around it and runs cooler than the formula predicts for its width, while a long one behaves like a narrow trace. Vias have their own current limits, set by plating thickness and diameter. Check necks and via arrays separately.

How were the numbers checked?

A separate Python implementation computes the same quantities in millimetres rather than mils and matches the calculator to the displayed digits. As an anchor against published calculators, 1 A, 10 °C and 1 oz outer copper gives about 12 mil.

References

  1. IPC-2221, "Generic Standard on Printed Board Design", conductor current-carrying capacity (the curve fit I = k·ΔT^0.44·A^0.725, k = 0.048 external and 0.024 internal).
  2. IPC-2152, "Standard for Determining Current Carrying Capacity in Printed Board Design" (newer charts based on new test data, including the influence of board thickness and copper planes).
  3. The values on this page were recomputed independently in Python.

Results are engineering estimates. Verify your design with datasheets, simulation and measurement.